10105/2/1 Honeywell FSC Module / Fail Safe High Density Analog Input Module
Ironman Technology Co.,LTD
Featured Brand:
● HONEYWELL ● AB ● OMRON ●SIEMENS ●SCHNEIDER
● ROSEMOUNT● ABB ● NOTIFIER ●MTL ● GE ●And many more !
10001/R/1 Virtual Bus Driver Card Honeywell Fail Safe High Density Analog Input Module
Lead time:3-5 days
New with one year warranty
Description
The Central Part (CP) of the FSC system is connected to the I/O level via the vertical bus driver (VBD) modules, which are located in the Central Part rack. A maximum of 14 vertical bus drivers can be installed per Central Part. Each vertical bus driver can support up to 10 horizontal bus driver (HBD) modules. The maximum distance between a vertical bus driver and any I/O rack on the vertical bus is 5 m (16.4 ft).
The 10001/1/1 and 10001/R/1 modules consist of two parts (see Figure 3): • electronic part (mainboard), and • wiring part (10001/A/1). The bolts on the 96-pin connector are used to secure the 10001/A/1 part of the VBD to the 19-inch rack. This allows exchange of the electronic part of the VBD without disconnecting the vertical bus flatcable.
Applications Table 1 below shows which vertical bus drivers can be used in the various configurations. Table 1 Application of 10001/1/1 & 10001/R/1 VBDs
Configurations with redundant Central Parts and non-redundant I/O require 10001/R/1 VBDs, because the relay on the 10001/R/1 disconnects the VBD from the vertical bus in case of a Central Part shutdown (via an on-board watchdog on the VBD or via software). Vertical bus The vertical bus flatcable connects the vertical bus drivers (VBDs, 10001/1/1 or 10001/R/1) to the horizontal bus drivers (HBDs, 10100/1/1 or 10100/2/1). For details on vertical buses refer to the 'V-Buses' data sheet.
Technical data The 10001/1/1 & 10001/R/1 modules have the following specifications: General Type number: 10001/1/1 Approvals: CE, TÜV, UL Software versions: all Space requirements: 4 TE, 3 HE (= 4 HP, 3U) Power Power requirements: 5 Vdc 225 mA Ripple content: < 50 mV p-p General Type number: 10001/R/1 Approvals: CE, TÜV, UL Software versions: all Space requirements: 4 TE, 3 HE (= 4 HP, 3U) Power Power requirements: 5 Vdc 275 mA Ripple content: < 50 mV p-p Note: Do not remove or replace these modules while the power to their Central Part is on.